source: trunk/exports/template_powder.cif @ 3246

Last change on this file since 3246 was 1130, checked in by toby, 8 years ago

CIF export: use G2 T & P values, fix profile inclusion to show all hists

File size: 3.1 KB
Line 
1# GSAS-II powder instrument template file
2
3data_Instrument_Template
4#==============================================================================
5# 9. INSTRUMENT CHARACTERIZATION
6
7_exptl_special_details
8; ?
9;
10
11# if regions of the data are excluded, the reason(s) are supplied here:
12_pd_proc_info_excluded_regions
13; ?
14;
15
16# The following item is used to identify the equipment used to record
17# the powder pattern when the diffractogram was measured at a laboratory
18# other than the authors' home institution, e.g. when neutron or synchrotron
19# radiation is used.
20
21_pd_instr_location
22; ?
23;
24_pd_calibration_special_details           # description of the method used
25                                          # to calibrate the instrument
26; ?
27;
28
29_diffrn_source                    ?       
30_diffrn_source_target             ?
31_diffrn_source_type               ?
32_diffrn_measurement_device_type   ?       
33_diffrn_detector                  ?       
34_diffrn_detector_type             ?       # make or model of detector
35
36_pd_meas_scan_method              ?       # options are 'step', 'cont',
37                                          # 'tof', 'fixed' or
38                                          # 'disp' (= dispersive)
39_pd_meas_special_details
40;  ?
41;
42
43# The following two items identify the program(s) used (if appropriate).
44_computing_data_collection        ?       
45_computing_data_reduction         ?                   
46
47# Describe any processing performed on the data, prior to refinement.
48# For example: a manual Lp correction or a precomputed absorption correction
49_pd_proc_info_data_reduction      ?
50
51# The following item is used for angular dispersive measurements only.
52
53_diffrn_radiation_monochromator   ?       
54
55# The following items are used to define the size of the instrument.
56# Not all distances are appropriate for all instrument types.
57
58_pd_instr_dist_src/mono           ?
59_pd_instr_dist_mono/spec          ?
60_pd_instr_dist_src/spec           ?
61_pd_instr_dist_spec/anal          ?
62_pd_instr_dist_anal/detc          ?
63_pd_instr_dist_spec/detc          ?
64
65# 10. Specimen size and mounting information
66
67# The next three fields give the specimen dimensions in mm.  The equatorial
68# plane contains the incident and diffracted beam.
69
70_pd_spec_size_axial               ?       # perpendicular to
71                                          # equatorial plane
72
73_pd_spec_size_equat               ?       # parallel to
74                                          # scattering vector
75                                          # in transmission
76
77_pd_spec_size_thick               ?       # parallel to
78                                          # scattering vector
79                                          # in reflection
80
81_pd_spec_mounting                         # This field should be
82                                          # used to give details of the
83                                          # container.
84; ?
85;
86
87_pd_spec_mount_mode               ?       # options are 'reflection'
88                                          # or 'transmission'
89   
90_pd_spec_shape                    ?       # options are 'cylinder'
91                                          # 'flat_sheet' or 'irregular'
92
Note: See TracBrowser for help on using the repository browser.