Ignore:
Timestamp:
Oct 1, 2012 10:34:46 AM (10 years ago)
Author:
ehanson
Message:

Updated documentation with opisys info

File:
1 edited

Legend:

Unmodified
Added
Removed
  • cssboy_deployment/docs/source/configure.rst

    r1062 r1123  
    2525        ``Switch Workspace...``.
    2626
    27 :index:`APS_sr` Project
    28 ===================================
    29 
    30 .. warning::  This section needs to be worked out.
    31 
    32 ..
    33         this work has not been done yet,
    34         the screens are not ready,
    35         the instructions are not ready
    36 
    37 .. TODO
    38         Do NOT forget to update the OPI Search Path instructions, when these screens become available
     27:index:`APS System` Project (opisys)
     28====================================
     29
     30Add OPI screens from the APS System as a project.
     31
     32#. Select menu ``File-->Import ...``
     33#. Open ``General`` category,
     34   select ``Existing Projects into Workspace``,
     35   click ``Next`` button
     36#. Click ``Browse ...`` button (in *Import* window)
     37#. Navigate to wherever you checked out the ``opisys/`` folder
     38#. Click ``Ok`` button
     39#. Click ``Finish`` button (in *Import* window)
    3940
    4041:index:`synApps` Project
     
    4849   click ``Next`` button
    4950#. Click ``Browse ...`` button (in *Import* window)
    50 #. navigate to ``/APSshare/epics/synApps_5_6/support/``
     51#. Navigate to ``/APSshare/epics/synApps_5_6/support/``
    5152   (or ``/usr/local/epics/synAppsSVN/support/`` or wherever)
    5253#. Click ``Ok`` button
     
    191192Change the text in for "OPI Search Path" to this really long string (all one line)::
    192193
    193                 /synApps/areaDetector/ADApp/op/opi | /synApps/asyn/opi/boy | /synApps/autosave/asApp/op/opi | /synApps/busy/busyApp/op/opi | /synApps/calc/calcApp/op/opi | /synApps/camac/camacApp/op/opi | /synApps/dac128V/dac128VApp/op/opi | /synApps/delaygen/delaygenApp/op/opi | /synApps/dxp/dxpApp/op/opi | /synApps/iocStats/op/opi | /synApps/ip/ipApp/op/opi | /synApps/ip330/ip330App/op/opi | /synApps/ipUnidig/ipUnidigApp/op/opi | /synApps/love/loveApp/op/opi | /synApps/mca/mcaApp/op/opi | /synApps/modbus/modbusApp/op/opi | /synApps/motor/motorApp/op/opi | /synApps/optics/opticsApp/op/opi | /synApps/quadEM/quadEMApp/op/opi | /synApps/softGlue/softGlueApp/op/opi | /synApps/sscan/sscanApp/op/opi | /synApps/std/stdApp/op/opi | /synApps/vac/vacApp/op/opi | /synApps/vme/vmeApp/op/opi | /synApps/xxx/xxxApp/op/opi
     194                /synApps/areaDetector/ADApp/op/opi | /synApps/asyn/opi/boy | /synApps/autosave/asApp/op/opi | /synApps/busy/busyApp/op/opi | /synApps/calc/calcApp/op/opi | /synApps/camac/camacApp/op/opi | /synApps/dac128V/dac128VApp/op/opi | /synApps/delaygen/delaygenApp/op/opi | /synApps/dxp/dxpApp/op/opi | /synApps/iocStats/op/opi | /synApps/ip/ipApp/op/opi | /synApps/ip330/ip330App/op/opi | /synApps/ipUnidig/ipUnidigApp/op/opi | /synApps/love/loveApp/op/opi | /synApps/mca/mcaApp/op/opi | /synApps/modbus/modbusApp/op/opi | /synApps/motor/motorApp/op/opi | /synApps/optics/opticsApp/op/opi | /synApps/quadEM/quadEMApp/op/opi | /synApps/softGlue/softGlueApp/op/opi | /synApps/sscan/sscanApp/op/opi | /synApps/std/stdApp/op/opi | /synApps/vac/vacApp/op/opi | /synApps/vme/vmeApp/op/opi | /synApps/xxx/xxxApp/op/opi | opisys/sr | opisys/sr/Gate_Pictures | opisys/sr/absApp | opisys/sr/blmApp | opisys/sr/bmbpm | opisys/sr/bunchIApp | opisys/sr/bunchPurity | opisys/sr/facilitiesApp | opisys/sr/fe | opisys/sr/flagApp | opisys/sr/id | opisys/sr/idbpm | opisys/sr/imagingApp | opisys/sr/iocinfoApp | opisys/sr/mpsApp | opisys/sr/mpsApp/uniq_gen | opisys/sr/operationsApp | opisys/sr/operationsApp/save | opisys/sr/p0fbApp | opisys/sr/psApp | opisys/sr/psApp/noiseMonitoring | opisys/sr/pss | opisys/sr/pss/adl | opisys/sr/scraperApp | opisys/sr/srTuneApp | opisys/sr/tuneApp | opisys/sr/vacApp | opisys/time/injtimeApp | opisys/time/mtimeApp
     195
    194196
    195197Keep clicking **Ok** until you dismiss all the dialogs.
     
    352354.. _calling.synapps.screens:
    353355
    354 Calling synApps screens
    355 ===========================================================
    356 
    357 Also, when calling a synApps .opi screen from the instrument or beam line,
     356Calling synApps or System screens
     357===========================================================
     358
     359Also, when calling a synApps or system .opi screen from the instrument or beam line,
    358360it is not necessary to use the full path since there is an OPI search path
    359361that will locate the screen.  Example, instead of::
Note: See TracChangeset for help on using the changeset viewer.