Link to NIST Center for Neutron Research home page Link to National Institute of Standards & Technology home page
Link to Tcl/Tk information


EXPGUI top Next page Previous page

EXPGUI, part 3

A.3 Histogram pane

The histogram pane is used to edit background and diffractometer constants for a histogram, as well as set damping and refinement flags for these parameters.

If "Multiple Histogram Selection" mode is set to "All", this pane is disabled. For other settings of this mode, groups of histograms can be selected and modified collectively.

If the EXPTOOL program (see the installation instructions) is installed, a button for adding histograms will appear on the bottom right on this pane, as seen below. If the program is not properly installed, no errors occur, but the button does not appear.

Note that the order that histograms appear in this pane is determined by the "Sort histograms by" option in the Options Menu.

EXPGUI Screen snapshot

If there is more than one phase present in the refinement, an extra box appears at the top of the pane to allow phase flags to be selected. This allows a phase to be used in some histograms but not in others. It also offers a simple way to effectively "delete" a phase by removing it from all histograms. Be sure to rerun POWPREF after changing the phase flags.
EXPGUI Screen snapshot

The pane appears slightly differently when "Multiple Histogram Selection" mode is set to a single histogram type. In this case diffractometer constants are edited in separate windows (see Global Editing of Parameters, below).

EXPGUI Screen snapshot

A.3.1 Editing background

EXPGUI Screen snapshot When the button labeled "Edit Background", (or "Globally Edit Background" or in the case where "Multiple Histogram Selection" mode is set to a single histogram type) is pressed, a window such as the one to the left is displayed. In the case where background coefficients are being edited for more than one histogram ( "Multiple Histogram Selection" mode must be set to a single histogram type) the entry boxes will appear blank and only those terms that are filled in will be changed when the "Set" button is pressed. This option is mostly useful when changing the background function or the number of terms for several histograms at a single time. Note that no changes are made until the "Set" button is pressed.

New! The "Fit Background Graphically" button is displayed only when a single histogram is selected for background editing. When this button is pressed, the BKGEDIT program is called to fit a background function to user-input fixed background points. See the BKGEDIT documentation for more information.

A.3.2 Global Editing of Parameters

EXPGUI Screen snapshot The dialog to the left shows how a diffractometer constant can be edited for more than one histogram ( "Multiple Histogram Selection" mode must be set to a single histogram type). This menu is also used to globally set the Phase Fraction.

A.3.3 Entering New Diffractograms

EXPGUI Screen snapshot Pressing the "Add New Histogram" button creates the dialog to the left. This can be used to select diffraction data to be used in the refinement, or if the "dummy histogram" boxed is selected, a set of diffraction data can be simulated.

In the case where diffraction data will be input, a data file and an instrument parameter file must be selected using the "Select File" buttons. The limit for reflection generation (maximum energy or two-theta, or minimum d-space or TOF) must be entered, as well as the units. If more than one bank is defined, either in the data file or in the instrument parameter file, the bank must be selected as well. Note that the data range can be edited at a later time using the EXCLEDT utility.

To view a plot of a data file, so that the range of the data may be viewed, the RAWPLOT program may be invoked using the "Run RAWPLOT" button. Note that EXPGUI cannot communicate the names of the data and instrument parameter files to RAWPLOT, so they must be reentered.


EXPGUI Screen snapshot When the dummy histogram option is selected, diffraction data can be simulated based a set of experimental constants described in an instrument parameter file. Note that most of these instrumental parameters, such as wavelength or DIFC can be edited on this pane or on the profile pane (the simulated pattern is also affected by constants on the scaling pane.) The 2-theta/energy/TOF range to be used for the computation, as well as the step size, must be entered before pressing the "Add" button. Note that once the histogram is added, this range and step size cannot be edited within EXPGUI at present. However, EXPEDT can be used to change these values.

EXPGUI Screen snapshot If errors are detected in the input, an error message is displayed detailing where the errors are found. Otherwise, the EXPTOOL program is run and the output is optionally displayed (See Show EXPTOOL output).


A.3.4 Editing the Data Range & Excluded Regions

The button at the bottom of the pane, labeled "Set Data Limits & Excluded Regions" invokes the EXCLEDT utility, which is used to modify the lower and upper data limits and can be used to add or delete excluded regions.

A.3.5 Setting Histogram Flags

EXPGUI Screen snapshot The button at the bottom of the pane, labeled "Set Histogram Use Flags" invokes a menu where the "Use"/"Do not use" flag for powder histogram can be set. When this flag is turned off, the histogram is ignored for subsequent computations, effectively removing from the experiment.

When these "Use" flags are changed, it is necessary to run POWPREF, to propogate the changes. After the "Save" button is pressed, a prompt such as the example below, is generated to run POWPREF. Note that GENLES may fail if POWPREF is not run after changing these flags.

EXPGUI Screen snapshot


EXPGUI top Next page Previous page
Brian Toby (Brian.Toby@NIST.GOV)
$Revision: 444 $ $Date: 2009-12-04 23:06:16 +0000 (Fri, 04 Dec 2009) $