EXPGUI top | Next page | Previous page |
---|
If the EXPTOOL program (see the installation instructions) is installed, buttons for adding phases and atoms will appear on this pane, as seen below. If the program is not properly installed, no errors occur, but the buttons do not appear.
Note that the order that atoms appear in this pane is
determined by the
"Sort Atoms by" option
in the Options Menu.
The parameter used for sorting is designated
with a "*" on the title line above the atoms.
Clicking on this title line rotates through the sorting modes.
If one or more atoms have been selected
(see Mouse Actions), it is possible
to transform the atom coordinates, globally set occupancy or Uiso (Uequiv)
values for the selected atoms, or erase the selected atoms, by pressing the
"Xform atom(s)" button. It is also possible to transform the selected atoms
from isotropic to anisotropic, or the reverse.
Note that no changes are actually made, until the
"Transform Coordinates", "Set Occupancies",... buttons are pressed.
After the "Continue" button is pressed, the spacegroup is checked and the
generated symmetry operators are shown. These should be checked carefully,
as GSAS will correctly generate a variety of standard and non-standard
spacegroups, but it is fussy about spacing: for example "R 3 2" and "R 32"
describe different (non-standard) space groups.
The EXPTOOL program is then run and the output is optionally displayed (See Show EXPTOOL output).
If atom coordinates have been read from a file, along with the
cell and space group, the "add new atoms" dialog is then shown, with the
atoms displayed (as below.)
If the file contains atoms that should not be included
in the .EXP file, the "Use" button to the
right of each atom can be deselected to prevent the atom from being used.
In the case of reading PowderCell .CEL files, the code may
have to translate coordinates to shift from an Origin 1 setting
to an Origin 2 setting. (GSAS, like many other crystallography programs,
assumes that if a center of symmetry is present, it is located at the origin.)
If this is done a message like the one to the left is displayed.
Once the "Continue button is pressed, the space group is checked, as is shown in the Add Phase section. A table is then generated for input of atoms, very similar to that in the Add Phase section. If atom coordinates have been read from a file these atoms are included in the table. It should be noted that when a phase is replaced in EXPGUI, all atoms in that phase are erased. If the current atom positions are to be retained, the "Reenter current atoms" box in the initial "Replace phase" dialog should be checked, these atoms will also be included in the table.
Note that no changes are made until after the "Continue" button
is pressed on the "Enter Atoms" dialog, so that is is safe to
press "Cancel" at any point.
EXPGUI top | Next page | Previous page |
---|