EXPGUI top | Next page | Previous page |
---|
Note that these constraints are only applied to shifts, but not to the actual values. This means that, for example, if two atoms are constrained so that the shift on their occupancy is the same, but the initial occupancies differ, the in occupancy difference will not change as the values refine.
Due to the way GSAS implements constraints, a parameter can be included in only one constraint. Should one or more parameters be constrained twice, the refinement results are unpredictable.
To delete one or more constraints, click on the appropriate checkbuttons in the Delete column and the press the Delete button, below.
When the edit button for a constraint is pressed, the constraint is
opened for editing. Controls are available to select the phase, variable,
multiplier and atom(s). Note that for atom selection, use of the control key
and the left mouse button allow individual atoms to be selected or deselected.
Shift and the left mouse button allow ranges of atoms to be selected and the
right mouse button selects all atoms
(see Mouse Actions).
Note that it is inappropriate to constrain different types of parameters together, for example X and Uiso. The left-most variable button is the "master" which determines what variable are allowed in the other variable buttons.
When the "New Constraint" button is pressed, a blank constraint editing window is opened. Note that any variable to the right may then be selected, including two special codes, Uxx and XYZU. XYZU creates four constraints, requiring the shifts on x, y, z and Uiso to be the same for all the selected atoms. Uxx does the same for the six anisotropic displacement parameters. These special codes are valuable for atoms that share a site.
Note that only 100 parameters may be included in a constraint, with one exception. When shifts for Uiso for all atoms in a phase are constrained, this counts as a single parameter. If more than 100 parameters are entered for a constraint, an error message is shown. Up to 2000 atomic constraints may be entered. EXPGUI does not warn if you exceed this limit.
To delete one or more constraints, click on the appropriate checkbuttons in the Delete column and the press the Delete button, below.
When the edit button for a constraint is pressed, the constraint is opened for editing, as shown below. Listboxes contain the available phases and histograms. Only the histograms of the same data type (TOF, CW or ED) are included, but no check is made to ensure that the selected phase/histogram combinations all have the same profile type. Note that for phase and histogram selection, use of the control key and the left mouse button allow individual items to be selected or deselected. Shift and the left mouse button allow ranges of items to be selected and the right mouse button selects all phases or histograms. (see Mouse Actions).
EXPGUI top | Next page | Previous page |
---|