Changeset 409 for trunk


Ignore:
Timestamp:
Dec 4, 2009 5:05:41 PM (14 years ago)
Author:
toby
Message:

# on 2001/08/24 18:56:53, toby did:
updates

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/doc/expgui2.html

    • Property rcs:date changed from 2000/10/18 00:11:17 to 2001/08/24 18:56:53
    • Property rcs:lines changed from +2 -2 to +33 -9
    • Property rcs:rev changed from 1.8 to 1.9
    r332 r409  
    5656determined by the
    5757<a href="expguic.html#sortatoms">"Sort Atoms by"</a> option
    58 in the Options Menu. <IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
     58in the Options Menu. <IMG SRC="note.gif" alt="Note!">
    5959The parameter used for sorting is designated
    6060with a "*" on the title line above the atoms.
    61 <IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
     61<IMG SRC="note.gif" alt="Note!">
    6262Clicking on this title line rotates through the sorting modes.
    6363</DL></DL>
     
    6666<a name="xform"></a>
    6767<img SRC="2a.gif" align=LEFT alt="EXPGUI Screen snapshot">
    68 <IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
     68<IMG SRC="note.gif" alt="Note!">
    6969If one or more atoms have been selected
    7070<A href="expgui.html#mouseactions">(see Mouse Actions)</A>, it is possible
     
    8383When the "Add Phase" button is pressed, a dialog is created where the
    8484space group and unit cell constants can be entered (below).
    85 <IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
     85<IMG SRC="note.gif" alt="Note!">
    8686By using the
    8787"Import phase from:" button at the lower right, one can read this information,
     
    109109atoms displayed (as below.)
    110110If the file contains atoms that should not be included
    111 in the .EXP file, the "Use" button to the
     111in the .EXP file, the "Use Flag" button to the
    112112right of each atom can be deselected to prevent the atom from being used.
    113113<img SRC="2d.gif" align=LEFT alt="EXPGUI Screen snapshot">
     114<br clear=all>
     115Atoms will be included in the phase in the order they appear in the table.
     116<IMG SRC="new.gif" alt="New!">
     117This order can be changed by pressing the buttons in the top row of the
     118table, which sorts the atoms according to the selected column. Note that
     119if the "Use Flag" button is deselected, the atom appears at the bottom
     120of the table.
     121<P>
     122When the "Add Atoms" button is pressed, the table is scanned for errors
     123such as invalid numbers or unknown atom types. If an error is encountered,
     124a message is displayed listing the problem(s). Corrections can then be
     125made to the table before pressing the "Add Atoms" button again.
    114126<br clear=all><P>
    115127<img SRC="2b1.gif" align=LEFT alt="EXPGUI Screen snapshot">
     
    118130to an Origin 2 setting. (GSAS, like many other crystallography programs,
    119131assumes that if a center of symmetry is present, it is located at the origin.)
    120 If this is done a message like the one to the left is displayed.
     132If this is done, a message like the one to the left is displayed.
    121133
    122134<br clear=all><P>
     
    126138<DL><DL>
    127139When the "Add New Atoms" button is pressed, a table is generated,
    128 as seen below, to enter atoms. <IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
     140as seen below, to enter atoms. <IMG SRC="note.gif" alt="Note!">
    129141The "Import atoms from:" button can
    130142be used to read atoms from a file.
     
    140152right of each atom can be deselected to prevent the atom from being used.
    141153<img SRC="2e.gif" align=LEFT alt="EXPGUI Screen snapshot">
     154<br clear=all><P>
     155Atoms will be added to the phase in the order they appear in the table.
     156<IMG SRC="new.gif" alt="New!">
     157This order can be changed by pressing the buttons in the top row of the
     158table, which sorts the atoms according to the selected column. Note that
     159if the "Use Flag" button is deselected, the atom appears at the bottom
     160of the table.
     161<P>
     162When the "Add Atoms" button is pressed, the table is scanned for errors
     163such as invalid numbers or unknown atom types. If an error is encountered,
     164a message is displayed listing the problem(s). Corrections can then be
     165made to the table before pressing the "Add Atoms" button again.
    142166
    143167<br clear=all><P>
     
    145169<a name="replacephase"></a><h4>
    146170A.2.3 Replace Phase
    147 <IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
     171<IMG SRC="note.gif" alt="Note!">
    148172</h4>
    149173<DL><DL>
Note: See TracChangeset for help on using the changeset viewer.