Changeset 310
- Timestamp:
- Dec 4, 2009 5:03:55 PM (14 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/doc/expgui3.html
- Property rcs:date changed from 2000/10/03 23:28:06 to 2000/10/12 21:15:58
- Property rcs:lines changed from +3 -3 to +73 -0
- Property rcs:rev changed from 1.4 to 1.5
r294 r310 56 56 <img SRC="3.gif" align=TEXTTOP alt="EXPGUI Screen snapshot"> 57 57 <P> 58 <DL><DL> 58 59 If there is more than one phase present in the refinement, 59 60 an extra box appears at the top of the pane to allow phase flags … … 62 63 phase by removing it from all histograms. Be sure to rerun POWPREF after 63 64 changing the phase flags. 65 </DL></DL> 64 66 <img SRC="3a.gif" align=TEXTTOP alt="EXPGUI Screen snapshot"> 67 <br clear=all> 68 <P> 69 <DL><DL> 70 The pane appears slightly differently when 71 <A href="expgui.html#multiplehistogram"> 72 "Multiple Histogram Selection" mode</A> is set to a single histogram type. 73 In this case diffractometer constants are edited in separate windows (see 74 <a href="#EditParm">Global Editing of Parameters</a>, below). 75 <P> 76 </DL></DL> 77 <img SRC="3c.gif" align=TEXTTOP alt="EXPGUI Screen snapshot"> 78 <br clear=all> 65 79 80 <a name="EditBackground"></a> 81 <h3>A.3.1 Editing background</h3> 82 <DL><DL> 83 <img SRC="3b.gif" align=LEFT alt="EXPGUI Screen snapshot"> 84 When the button labeled "Edit Background", (or "Globally Edit Background" 85 or in the case where <A href="expgui.html#multiplehistogram"> 86 "Multiple Histogram Selection" mode</A> is set to a single histogram type) 87 is pressed, a window such as the one 88 to the left is displayed. In the case where background coefficients 89 are being edited for more than one histogram 90 (<A href="expgui.html#multiplehistogram"> 91 "Multiple Histogram Selection" mode</A> must be 92 set to a single histogram type) the entry boxes will appear blank 93 and only those terms that are filled in will be changed when the "Set" 94 button is pressed. 95 This option is mostly useful when changing the background function or the 96 number of terms for several histograms at a single time. 97 Note that no changes are made until the "Set" 98 button is pressed. 99 <br clear=all> 100 </DL></DL> 101 102 <a name="EditParm"></a> 103 <h3>A.3.2 Global Editing of Parameters</h3> 104 <DL><DL> 105 <img SRC="3d.gif" align=LEFT alt="EXPGUI Screen snapshot"> 106 The dialog to the left shows how 107 a difractometer constant can be 108 edited for more than one histogram 109 (<A href="expgui.html#multiplehistogram"> 110 "Multiple Histogram Selection" mode</A> must be 111 set to a single histogram type). 112 This menu is also used to globally set the 113 <A href="expgui4.html">Phase Fraction</A>. 114 <br clear=all> 115 116 </DL></DL> 117 118 <a name="AddHist"></a> 119 <h3>A.3.3 Entering New Diffractograms</h3> 120 <DL><DL> 121 <img SRC="3e.gif" align=LEFT alt="EXPGUI Screen snapshot"> 122 Pressing the "Add New Histogram" button creates the dialog 123 to the left. A data file and an instrument parameter file are 124 selected using the "Select File" buttons. If more than 125 one bank is defined, the bank must be selected and the maximum 126 data value to be considered, must be entered. Note that the 127 units for the maximum (minimum for d-spaces) must also be selected. 128 To view a data file, to see the extent of the data, the "Run RAWPLOT" 129 button may be used. Note that EXPGUI cannot communicate the names 130 of the data and instrument parameter files to RAWPLOT, so they must be 131 reentered. 132 <P> 133 <a name="AddHistErr"></a> 134 If errors are detected in the input, an error message is displayed detailing where 135 the errors are found. Otherwise, the EXPTOOL program is run. 136 137 and the output is displayed 138 </DL></DL> 66 139 <hr> 67 140 <TABLE BORDER BGCOLOR="#FFFF40" ALIGN=RIGHT>
Note: See TracChangeset
for help on using the changeset viewer.