Changeset 310


Ignore:
Timestamp:
Dec 4, 2009 5:03:55 PM (14 years ago)
Author:
toby
Message:

# on 2000/10/12 21:15:58, toby did:
add anchors & more text for on-line help

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/doc/expgui3.html

    • Property rcs:date changed from 2000/10/03 23:28:06 to 2000/10/12 21:15:58
    • Property rcs:lines changed from +3 -3 to +73 -0
    • Property rcs:rev changed from 1.4 to 1.5
    r294 r310  
    5656<img SRC="3.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
    5757<P>
     58<DL><DL>
    5859If there is more than one phase present in the refinement,
    5960an extra box appears at the top of the pane to allow phase flags
     
    6263phase by removing it from all histograms. Be sure to rerun POWPREF after
    6364changing the phase flags.
     65</DL></DL>
    6466<img SRC="3a.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
     67<br clear=all>
     68<P>
     69<DL><DL>
     70The pane appears slightly differently when
     71<A href="expgui.html#multiplehistogram">
     72"Multiple Histogram Selection" mode</A> is set to a single histogram type.
     73In this case diffractometer constants are edited in separate windows (see
     74<a href="#EditParm">Global Editing of Parameters</a>, below).
     75<P>
     76</DL></DL>
     77<img SRC="3c.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
     78<br clear=all>
    6579
     80<a name="EditBackground"></a>
     81<h3>A.3.1 Editing background</h3>
     82<DL><DL>
     83<img SRC="3b.gif" align=LEFT alt="EXPGUI Screen snapshot">
     84When the button labeled "Edit Background", (or "Globally Edit Background"
     85or in the case where <A href="expgui.html#multiplehistogram">
     86"Multiple Histogram Selection" mode</A> is set to a single histogram type)
     87is pressed, a window such as the one
     88to the left is displayed. In the case where background coefficients
     89are being edited for more than one histogram
     90(<A href="expgui.html#multiplehistogram">
     91"Multiple Histogram Selection" mode</A> must be
     92set to a single histogram type) the entry boxes will appear blank
     93and only those terms that are filled in will be changed when the "Set"
     94button is pressed.
     95This option is mostly useful when changing the background function or the
     96number of terms for several histograms at a single time.
     97Note that no changes are made until the "Set"
     98button is pressed.
     99<br clear=all>
     100</DL></DL>
     101
     102<a name="EditParm"></a>
     103<h3>A.3.2 Global Editing of Parameters</h3>
     104<DL><DL>
     105<img SRC="3d.gif" align=LEFT alt="EXPGUI Screen snapshot">
     106The dialog to the left shows how
     107a difractometer constant can be
     108edited for more than one histogram
     109(<A href="expgui.html#multiplehistogram">
     110"Multiple Histogram Selection" mode</A> must be
     111set to a single histogram type).
     112This menu is also used to globally set the
     113<A href="expgui4.html">Phase Fraction</A>.
     114<br clear=all>
     115
     116</DL></DL>
     117
     118<a name="AddHist"></a>
     119<h3>A.3.3 Entering New Diffractograms</h3>
     120<DL><DL>
     121<img SRC="3e.gif" align=LEFT alt="EXPGUI Screen snapshot">
     122Pressing the "Add New Histogram" button creates the dialog
     123to the left. A data file and an instrument parameter file are
     124selected using the "Select File" buttons. If more than
     125one bank is defined, the bank must be selected and the maximum
     126data value to be considered, must be entered. Note that the
     127units for the maximum (minimum for d-spaces) must also be selected.
     128To view a data file, to see the extent of the data, the "Run RAWPLOT"
     129button may be used. Note that EXPGUI cannot communicate the names
     130of the data and instrument parameter files to RAWPLOT, so they must be
     131reentered.
     132<P>
     133<a name="AddHistErr"></a>
     134If errors are detected in the input, an error message is displayed detailing where
     135the errors are found. Otherwise, the EXPTOOL program is run.
     136
     137 and the output is displayed
     138</DL></DL>
    66139<hr>
    67140<TABLE BORDER BGCOLOR="#FFFF40" ALIGN=RIGHT>
Note: See TracChangeset for help on using the changeset viewer.