source: trunk/doc/expgui5.html @ 335

Last change on this file since 335 was 335, checked in by toby, 13 years ago

# on 2000/10/18 00:11:17, toby did:
fixup formatting

  • Property rcs:author set to toby
  • Property rcs:date set to 2000/10/18 00:11:17
  • Property rcs:lines set to +2 -2
  • Property rcs:rev set to 1.6
  • Property rcs:state set to Exp
  • Property svn:keywords set to Author Date Revision Id
File size: 3.7 KB
Line 
1<html>
2<head>
3   <META NAME="Author" CONTENT="Brian H. Toby">
4   <title>EXPGUI</title>
5</head>
6<BODY BGCOLOR="#FFFFFF">
7
8<A HREF=http://www.ncnr.nist.gov>
9<IMG SRC="http://www.ncnr.nist.gov/images/ncnrtrans.gif" 
10alt="Link to NIST Center for Neutron Research home page"
11ALIGN=RIGHT></A>
12<A HREF=http://www.nist.gov>
13<IMG SRC="http://www.ncnr.nist.gov/images/webidblue_2lineright.gif" 
14alt="Link to National Institute of Standards & Technology home page"
15ALIGN=LEFT></A>
16<CENTER>
17<A Href="http://www.ncnr.nist.gov/programs/crystallography/software/tclpkgs.html">
18<IMG SRC="tcltklogo100.gif" 
19alt="Link to Tcl/Tk information">
20</CENTER></A>
21<br clear=all><hr>
22
23<TABLE BORDER BGCOLOR="#FFFF40" ALIGN=RIGHT>
24<TR><TH><A  Href="expgui.html">EXPGUI top</A> 
25</TH><TH><A Href="expgui6.html">Next page</A>
26</TH><TH><A Href="expgui4.html">Previous page</A>
27</TH></TR></TABLE><BR CLEAR=ALL>
28
29<center><h1>
30EXPGUI, part 5
31</h1></center>
32
33<h3>A.5 Profile pane</h3> 
34<DL><DL>
35The Profile pane is used to edit the profile values as well as
36their refinement flags and damping value.
37Note that there will be a set of profile parameters for each
38phase present in each histogram.
39<IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
40The "Change Type" button is used to select a new profile type for one
41or more histogram/phase combinations.
42<P>
43Note that the order that histograms appear in this
44pane is determined by the
45<a href="expguic.html#sorthist">"Sort histograms by"</a> option in
46the Options Menu.
47</DL></DL>
48<img SRC="5.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
49<DL><DL>
50When more than one phase is present in the histogram,
51the profiles for all phases are shown.
52</DL></DL>
53<img SRC="5a.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
54<DL><DL>
55
56<P>
57If
58<A href="expgui.html#multiplehistogram">
59"Multiple Histogram Selection" mode</A> is set to "All",
60this pane is disabled. For other settings of this mode,
61profile values and settings can be collectively
62modified for groups of histograms and the pane appears slightly
63differently
64</DL></DL>
65<img SRC="5c.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
66
67
68<a name="ChangeType">
69<h4>A.5.1 Edit Profile Type</h4> 
70<DL><DL>
71Pressing the "Change Type" button causes a window like the one below to
72be displayed.
73<P><img SRC="5b.gif" align=TEXTTOP alt="EXPGUI Screen snapshot"><BR><P>
74Note that the default profile values are taken from the instrument parameter
75file (in the example above, a profile was selected where no
76such default values were defined and the current values (where appropriate)
77are taken from the current profile function. Through use of the appropriate
78buttons, selected values can be retained from the current profile when
79the function is changed or can be reset to default values. This latter
80capability can be useful even when not changing the profile type, if the
81profile terms have refined into a false minimum.
82
83</DL></DL>
84<a name="GlobalEdit">
85</a><h4>A.5.2 Profile pane</h4> 
86<DL><DL>
87<img SRC="5d.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
88<P>
89When the button labeled "Global Edit" is pressed
90(<A href="expgui.html#multiplehistogram">
91"Multiple Histogram Selection" mode</A> must be
92set to a single histogram type) the dialog above will be displayed.
93The entry boxes will appear blank
94and only those terms that are filled in will be changed when the "Set"
95button is pressed.
96
97</DL></DL><hr>
98<TABLE BORDER BGCOLOR="#FFFF40" ALIGN=RIGHT>
99<TR><TH><A  Href="expgui.html">EXPGUI top</A> 
100</TH><TH><A Href="expgui6.html">Next page</A>
101</TH><TH><A Href="expgui4.html">Previous page</A>
102</TH></TR></TABLE>
103
104<a href="http://www.ncnr.nist.gov/staff/toby/">Brian Toby</a> (<a href="mailto:brian.toby@nist.gov">Brian.Toby@NIST.GOV</a>)
105<br>
106$Revision: 335 $ $Date: 2009-12-04 23:04:20 +0000 (Fri, 04 Dec 2009) $
107</body>
108</html>
Note: See TracBrowser for help on using the repository browser.