1 | <html> |
---|
2 | <head> |
---|
3 | <META NAME="Author" CONTENT="Brian H. Toby"> |
---|
4 | <title>EXPGUI</title> |
---|
5 | </head> |
---|
6 | <BODY BGCOLOR="#FFFFFF"> |
---|
7 | |
---|
8 | <A HREF=http://www.ncnr.nist.gov> |
---|
9 | <IMG SRC="http://www.ncnr.nist.gov/images/ncnrtrans.gif" |
---|
10 | alt="Link to NIST Center for Neutron Research home page" |
---|
11 | ALIGN=RIGHT></A> |
---|
12 | <A HREF=http://www.nist.gov> |
---|
13 | <IMG SRC="http://www.ncnr.nist.gov/images/webidblue_2lineright.gif" |
---|
14 | alt="Link to National Institute of Standards & Technology home page" |
---|
15 | ALIGN=LEFT></A> |
---|
16 | <CENTER> |
---|
17 | <A Href="http://www.ncnr.nist.gov/programs/crystallography/software/tclpkgs.html"> |
---|
18 | <IMG SRC="tcltklogo100.gif" |
---|
19 | alt="Link to Tcl/Tk information"> |
---|
20 | </CENTER></A> |
---|
21 | <hr> |
---|
22 | |
---|
23 | <center><h1> |
---|
24 | EXPGUI |
---|
25 | </h1></center> |
---|
26 | <A Href="expgui.html">EXPGUI top</A> |
---|
27 | <h3>A.5 Profile pane</h3> |
---|
28 | <DL><DL> |
---|
29 | The Profile pane is used to edit the profile values as well as |
---|
30 | their refinement flags and damping value. |
---|
31 | Note that there will be a set of profile parameters for each |
---|
32 | phase present in each histogram. |
---|
33 | <IMG SRC="new.gif" HEIGHT=13 WIDTH=36> |
---|
34 | The "Change Type" button is used to select a new profile type for one |
---|
35 | or more histogram/phase combinations. |
---|
36 | <P> |
---|
37 | If |
---|
38 | <A href="expgui.html#multiplehistogram"> |
---|
39 | "Multiple Histogram Selection" mode</A> is set to "All", |
---|
40 | this pane is disabled. For other settings of this mode, |
---|
41 | profile values and settings can be collectively |
---|
42 | modified for groups of histograms. |
---|
43 | <P> |
---|
44 | Note that the order that histograms appear in this |
---|
45 | pane is determined by the |
---|
46 | <a href="expguic.html#sorthist">"Sort histograms by"</a> option in |
---|
47 | the Options Menu. |
---|
48 | </DL></DL> |
---|
49 | <img SRC="5.gif" align=TEXTTOP> |
---|
50 | <DL><DL> |
---|
51 | When more than one phase is present in the histogram, |
---|
52 | the profiles for all phases are shown. |
---|
53 | </DL></DL> |
---|
54 | <img SRC="5a.gif" align=TEXTTOP> |
---|
55 | <DL><DL> |
---|
56 | |
---|
57 | Pressing the "Change Type" button causes a window like the one below to |
---|
58 | be displayed. |
---|
59 | <P><img SRC="5b.gif" align=TEXTTOP><BR><P> |
---|
60 | Note that the default profile values are taken from the instrument parameter |
---|
61 | file (in the example above, a profile was selected where no |
---|
62 | such default values were defined and the current values (where appropriate) |
---|
63 | are taken from the current profile function. Through use of the appropriate |
---|
64 | buttons, selected values can be retained from the current profile when |
---|
65 | the function is changed or can be reset to default values. This latter |
---|
66 | capability can be useful even when not changing the profile type, if the |
---|
67 | profile terms have refined into a false minimum. |
---|
68 | |
---|
69 | |
---|
70 | </DL></DL><hr> |
---|
71 | <A Href="expgui.html">EXPGUI top</A> |
---|
72 | |
---|
73 | <p><a href="http://www.ncnr.nist.gov/staff/toby/">Brian Toby</a> (<a href="mailto:brian.toby@nist.gov">Brian.Toby@NIST.GOV</a>) |
---|
74 | <br> |
---|
75 | $Revision: 246 $ $Date: 2009-12-04 23:02:50 +0000 (Fri, 04 Dec 2009) $ |
---|
76 | </body> |
---|
77 | </html> |
---|