source: trunk/doc/expgui5.html @ 296

Last change on this file since 296 was 296, checked in by toby, 13 years ago

# on 2000/10/03 23:28:06, toby did:
Add the NIST required ALT= tags to all images

  • Property rcs:author set to toby
  • Property rcs:date set to 2000/10/03 23:28:06
  • Property rcs:lines set to +5 -5
  • Property rcs:rev set to 1.4
  • Property rcs:state set to Exp
  • Property svn:keywords set to Author Date Revision Id
File size: 3.0 KB
RevLine 
[222]1<html>
2<head>
3   <META NAME="Author" CONTENT="Brian H. Toby">
4   <title>EXPGUI</title>
5</head>
6<BODY BGCOLOR="#FFFFFF">
7
8<A HREF=http://www.ncnr.nist.gov>
9<IMG SRC="http://www.ncnr.nist.gov/images/ncnrtrans.gif" 
10alt="Link to NIST Center for Neutron Research home page"
11ALIGN=RIGHT></A>
12<A HREF=http://www.nist.gov>
13<IMG SRC="http://www.ncnr.nist.gov/images/webidblue_2lineright.gif" 
14alt="Link to National Institute of Standards & Technology home page"
15ALIGN=LEFT></A>
16<CENTER>
17<A Href="http://www.ncnr.nist.gov/programs/crystallography/software/tclpkgs.html">
18<IMG SRC="tcltklogo100.gif" 
19alt="Link to Tcl/Tk information">
20</CENTER></A>
21<hr>
22
[275]23<TABLE BORDER BGCOLOR="#FFFF40" ALIGN=RIGHT>
24<TR><TH><A  Href="expgui.html">EXPGUI top</A> 
25</TH><TH><A Href="expgui6.html">Next page</A>
26</TH><TH><A Href="expgui4.html">Previous page</A>
27</TH></TR></TABLE><BR CLEAR=ALL>
28
[222]29<center><h1>
[275]30EXPGUI, part 5
[222]31</h1></center>
[275]32
[222]33<h3>A.5 Profile pane</h3> 
34<DL><DL>
35The Profile pane is used to edit the profile values as well as
36their refinement flags and damping value.
37Note that there will be a set of profile parameters for each
38phase present in each histogram.
[296]39<IMG SRC="new.gif" HEIGHT=13 WIDTH=36 alt="New!">
[222]40The "Change Type" button is used to select a new profile type for one
41or more histogram/phase combinations.
42<P>
43If
44<A href="expgui.html#multiplehistogram">
45"Multiple Histogram Selection" mode</A> is set to "All",
46this pane is disabled. For other settings of this mode,
47profile values and settings can be collectively
48modified for groups of histograms.
49<P>
50Note that the order that histograms appear in this
51pane is determined by the
52<a href="expguic.html#sorthist">"Sort histograms by"</a> option in
53the Options Menu.
54</DL></DL>
[296]55<img SRC="5.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
[246]56<DL><DL>
57When more than one phase is present in the histogram,
58the profiles for all phases are shown.
59</DL></DL>
[296]60<img SRC="5a.gif" align=TEXTTOP alt="EXPGUI Screen snapshot">
[246]61<DL><DL>
[222]62
[246]63Pressing the "Change Type" button causes a window like the one below to
64be displayed.
[296]65<P><img SRC="5b.gif" align=TEXTTOP alt="EXPGUI Screen snapshot"><BR><P>
[246]66Note that the default profile values are taken from the instrument parameter
67file (in the example above, a profile was selected where no
68such default values were defined and the current values (where appropriate)
69are taken from the current profile function. Through use of the appropriate
70buttons, selected values can be retained from the current profile when
71the function is changed or can be reset to default values. This latter
72capability can be useful even when not changing the profile type, if the
73profile terms have refined into a false minimum.
74
75
76</DL></DL><hr>
[275]77<TABLE BORDER BGCOLOR="#FFFF40" ALIGN=RIGHT>
78<TR><TH><A  Href="expgui.html">EXPGUI top</A> 
79</TH><TH><A Href="expgui6.html">Next page</A>
80</TH><TH><A Href="expgui4.html">Previous page</A>
81</TH></TR></TABLE>
[222]82
[275]83<a href="http://www.ncnr.nist.gov/staff/toby/">Brian Toby</a> (<a href="mailto:brian.toby@nist.gov">Brian.Toby@NIST.GOV</a>)
[222]84<br>
85$Revision: 296 $ $Date: 2009-12-04 23:03:41 +0000 (Fri, 04 Dec 2009) $
86</body>
87</html>
Note: See TracBrowser for help on using the repository browser.